Cogging torque

Cogging torque of electrical motors is the torque due to the interaction between the permanent magnets of the rotor and the stator slots of a Permanent Magnet (PM) machine. It is also known as detent or 'no-current' torque. This torque is position dependent and its periodicity per revolution depends on the number of magnetic poles and the number of teeth on the stator. Cogging torque is an undesirable component for the operation of such a motor. It is especially prominent at lower speeds, with the symptom of jerkiness. Cogging torque results in torque as well as speed ripple; however, at high speed the motor moment of inertia filters out the effect of cogging torque.

Reducing cogging torque

A summary of techniques used for reducing cogging torque:

Almost all the techniques used against to cogging torque also reduce the motor counter-electromotive force and so reduce the resultant running torque.

A slotless permanent magnet motor does not have any cogging torque.

Model railway motors

Model railway motors usually have a 2-pole permanent magnet and 3, 5 or 7 poles on the armature to reduce cogging torque.

Footnotes and References

See also


External links


This article is issued from Wikipedia - version of the 9/1/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.