Isobaric counterdiffusion

For other uses of "ICD", see ICD (disambiguation).

In physiology, isobaric counterdiffusion (ICD) is the diffusion of different gases into and out of tissues while under a constant ambient pressure, and the physiological effects of this phenomenon. The term inert gas counterdiffusion is sometimes used as a synonym, but can also be applied to situations where the ambient pressure changes.[1][2] It has relevance in mixed gas diving and anesthesiology

Background

Isobaric counterdiffusion was first described by Graves, Idicula, Lambertsen, and Quinn in 1973 in subjects who breathed one inert gas mixture (nitrogen or neon) while being surrounded by another (helium).[3][4]

Clinical Relevance

In medicine, ICD is the diffusion of gases in different directions that can increase the pressure inside open air spaces of the body and surrounding equipment.[5]

An example of this would be a patient breathing nitrous oxide in an operating room (surrounded by air). Cuffs on the endotracheal tubes must be monitored as nitrous oxide will diffuse into the air filled space causing the volume to increase. In laparoscopic surgery, nitrous oxide is avoided since the gas will diffuse into the abdominal or pelvic cavities causing an increase in internal pressure. In the case of a tympanoplasty, the skin flap will not lay down as the nitrous oxide will be diffusing into the middle ear.

Diving Relevance

In underwater diving, ICD is the diffusion of one inert gas into body tissues while another inert gas is diffusing out. While not strictly speaking a phenomenon of decompression, it is a complication that can occur during decompression, and that can result in the formation or growth of bubbles without changes in the environmental pressure.[6][7] If the gas that is diffusing into a tissue does so at a rate which exceeds the rate of the other leaving the tissue, it can raise the combined gas concentration in the tissue to a supersaturation sufficient to cause the formation or growth of bubbles, without changes in the environmental pressure, and in particular, without concurrent decompression. Two forms of this phenomenon have been described by Lambertsen:[1][8]

Superficial ICD

Superficial ICD (also known as Steady State Isobaric Counterdiffusion) occurs when the inert gas breathed by the diver diffuses more slowly into the body than the inert gas surrounding the body.[1][8][9]

An example of this would be breathing air in an heliox environment. The helium in the heliox diffuses into the skin quickly, while the nitrogen diffuses more slowly from the capillaries to the skin and out of the body. The resulting effect generates supersaturation in certain sites of the superficial tissues and the formation of inert gas bubbles. These isobaric skin lesions (urticaria) do not occur when the ambient gas is nitrogen and the breathing gas is helium.[10][9]

Deep tissue ICD

Deep tissue ICD (also known as Transient Isobaric Counterdiffusion) occurs when different inert gases are breathed by the diver in sequence.[1][8] The rapidly diffusing gas is transported into the tissue faster than the slower diffusing gas is transported out of the tissue.[7]

An example of this was shown in the literature by Harvey in 1977 as divers switched from a nitrogen mixture to a helium mixture (diffusivity of helium is 2.65 times faster than nitrogen),[7] they quickly developed itching followed by joint pain.[11] Saturation divers breathing hydreliox switched to a heliox mixture and developed symptoms of decompression sickness during Hydra V.[12] More recently, Doolette and Mitchell have described ICD as the basis for inner ear decompression sickness and suggest "breathing-gas switches should be scheduled deep or shallow to avoid the period of maximum supersaturation resulting from decompression".[13] It can also happen when saturation divers breathing hydreliox switch to a heliox mixture.[14]

There is another effect which can manifest as a result of the disparity in solubility between inert breathing gas diluents, which occurs in isobaric gas switches near the decompression ceiling between a low solubility gas (typically helium, and a higher solubility gas, typically nitrogen)[15][16]

An inner ear decompression model by Doolette and Mitchell suggests that a transient increase in gas tension after a switch from helium to nitrogen in breathing gas may result from the difference in gas transfer between compartments. If the transport of nitrogen into the vascular compartment by perfusion exceeds removal of helium by perfusion, while transfer of helium into the vascular compartment by diffusion from the perilymph and endolymph exceeds the counterdiffusion of nitrogen, this may result in a temporary increase in total gas tension, as the input of nitrogen exceeds the removal of helium, which can result in bubble formation and growth. This model suggests that diffusion of gases from the middle ear across the round window is negligible. The model is not necessarily applicable to all tissue types.[13]

ICD Prevention

Lambertsen made suggestions to help avoid ICD while diving.[1][8] If the diver is surrounded by or saturated with nitrogen, they should not breathe helium rich gases. Lambertson also proposed that gas switches that involve going from helium rich mixtures to nitrogen rich mixtures would be acceptable, but changes from nitrogen to helium should include recompression. However Doolette and Mitchell's more recent study of Inner Ear Decompression Sickness (IEDCS) now shows that the inner ear may not be well-modelled by common (e.g. Bühlmann) algorithms. Doolette and Mitchell propose that a switch from a helium-rich mix to a nitrogen-rich mix, as is common in technical diving when switching from trimix to nitrox on ascent, may cause a transient supersaturation of inert gas within the inner ear and result in IEDCS.[13] A similar hypothesis to explain the incidence of IEDCS when switching from trimix to nitrox was proposed by Steve Burton, who considered the effect of the much greater solubility of nitrogen than helium in producing transient increases in total inert gas pressure, which could lead to DCS under isobaric conditions.[17] Recompression with oxygen is effective for relief of symptoms resulting from ICD. However, Burton's model for IEDCS does not agree with Doolette and Mitchell's model of the inner ear. Doolette and Mitchell model the inner ear using solubility coefficients close to that of water.[13] They suggest that breathing-gas switches from helium-rich to nitrogen-rich mixtures should be carefully scheduled either deep (with due consideration to nitrogen narcosis) or shallow to avoid the period of maximum supersaturation resulting from the decompression. Switches should also be made during breathing of the largest inspired oxygen partial pressure that can be safely tolerated with due consideration to oxygen toxicity.[13]

A similar hypothesis to explain the incidence of IEDCS when switching from trimix to nitrox was proposed by Steve Burton, who considered the effect of the much greater solubility of nitrogen than helium in producing transient increases in total inert gas pressure, which could lead to DCS under isobaric conditions.[18]

Burton argues that effect of switching to Nitrox from Trimix with a large increase of nitrogen fraction at constant pressure has the effect of increasing the overall gas loading within particularly the faster tissues, since the loss of helium is more than compensated by the increase in nitrogen. This could cause immediate bubble formation and growth in the fast tissues. A simple rule for avoidance of ICD when gas switching at a decompression ceiling is suggested:[18]

This rule has been found to successfully avoid ICD on hundreds of deep trimix dives.[18]

A decompression planning software tool called Ultimate Planner attempts to predict ICD through modeling the inner ear as either aqueous (Mitchell and Doolette's approach) or lipid tissue (Burton's approach).[19]

See also

References

  1. 1 2 3 4 5 Hamilton, Robert W; Thalmann, Edward D (2003). "Decompression Practice". In Brubakk, Alf O; Neuman, Tom S. Bennett and Elliott's physiology and medicine of diving (5th ed.). United States: Saunders. pp. 477–8. ISBN 0-7020-2571-2. OCLC 51607923.
  2. Lambertson, Christian J; Bornmann, Robert C; Kent, MB, eds. (1979). Isobaric Inert Gas Counterdiffusion. 22nd Undersea and Hyperbaric Medical Society Workshop. UHMS Publication Number 54WS(IC)1-11-82. Retrieved 10 January 2010.
  3. Graves, DJ; Idicula, J; Lambertsen, Christian J; Quinn, JA (February 1973). "Bubble formation in physical and biological systems: a manifestation of counterdiffusion in composite media". Science. 179 (4073): 582–584. Bibcode:1973Sci...179..582G. doi:10.1126/science.179.4073.582. PMID 4686464. Retrieved 10 January 2010.
  4. Graves, DJ; Idicula, J; Lambertsen, Christian J; Quinn, JA (March 1973). "Bubble formation resulting from counterdiffusion supersaturation: a possible explanation for isobaric inert gas 'urticaria' and vertigo". Physics in medicine and biology. 18 (2): 256–264. Bibcode:1973PMB....18..256G. doi:10.1088/0031-9155/18/2/009. PMID 4805115. Retrieved 10 January 2010.
  5. Barash, PG; Cullen, BF; Stoelting, RK (2005). Clinical Anesthesia (5th Rev ed.). United States: Lippincott Williams & Wilkins. ISBN 0-7817-5745-2.
  6. Hamilton & Thalmann 2003, pp. 477–478.
  7. 1 2 3 Lambertson, Christian J (1989). Relations of isobaric gas counterdiffusion and decompression gas lesion diseases. In Vann, RD. "The Physiological Basis of Decompression". 38th Undersea and Hyperbaric Medical Society Workshop UHMS Publication Number 75(Phys)6-1-89. http://archive.rubicon-foundation.org/6853. Retrieved 10 January 2010.
  8. 1 2 3 4 Lambertson, Christian J (1989). "Relations of isobaric gas counterdiffusion and decompression gas lesion diseases". In Vann, RD. The Physiological Basis of Decompression. 38th Undersea and Hyperbaric Medical Society Workshop. UHMS Publication Number 75(Phys)6-1-89. Retrieved 10 January 2010.
  9. 1 2 D'Aoust, BG; White, R; Swanson, H; Dunford, RG; Mahoney, J (1982). "Differences in Transient and Steady State Isobaric Counterdiffusion". Report to the Office of Naval Research. Retrieved 10 January 2010.
  10. Hills, Brian A. (1979). Kent, MB, ed. "Counter transport of inert gases: Effects of steady state and transient gradients.". Isobaric Inert Gas Counterdiffusion. 22nd workshop, Chairs: Lambertsen, CJ; Bornmann, RC. Philadelphia, Pennsylvania.: Undersea Medical Society. p. 151. Retrieved 18 March 2016.
  11. Harvey, CA (1977). "Shallow saturation hyperbaric exposures to nitrogen-oxygen environments and isobaric switches to helium oxygen". Undersea Biomedical Research, Annual Meeting Abstract. Retrieved 10 January 2010.
  12. Rostain, JC; Lemaire, C; Gardette-Chauffour, MC; Naquet, R (1987). Bove; Bachrach; Greenbaum, eds. "Effect of the shift from hydrogen-helium-oxygen mixture to helium oxygen mixture during a 450 msw dive". Underwater and hyperbaric physiology IX. Bethesda, MD, USA: Undersea and Hyperbaric Medical Society.
  13. 1 2 3 4 5 Doolette, David J; Mitchell, Simon J (June 2003). "Biophysical basis for inner ear decompression sickness". Journal of Applied Physiology. 94 (6): 2145–50. doi:10.1152/japplphysiol.01090.2002 (inactive 2015-01-09). PMID 12562679. Retrieved 10 January 2010.
  14. Masurel, G; Gutierrez, N; Giacomoni, L (1987). "Hydrogen dive and decompression.". Abstract of the Undersea and Hyperbaric Medical Society, Inc. Annual Scientific Meeting held May 26–30, 1987. The Hyatt Regency Hotel, Baltimore, Maryland. Undersea and Hyperbaric Medical Society, Inc. Retrieved 14 March 2016.
  15. Partridge, Matthew. "Isobaric Inert Gas Counter diffusion" (PDF). Retrieved 14 March 2016.
  16. Burton, Steve (2011). "Isobaric Counter Diffusion How to avoid a Isobaric Counter Diffusion hit". ScubaEngineer.com. Retrieved 14 March 2016.
  17. Burton, Steve (December 2004). "Isobaric Counter Diffusion". ScubaEngineer. Retrieved 10 January 2010.
  18. 1 2 3 4 Burton, Steve (December 2004). "Isobaric Counter Diffusion". ScubaEngineer. http://www.scubaengineer.com/isobaric_counter_diffusion.htm. Retrieved 10 January 2010.
  19. Salama, Asser (2014). "Ultimate planner (deco software)". Tech Diving Mag. Asser Salama. Retrieved 17 March 2016.

External resources

Lambertsen/ U Penn isobaric counterdiffusion references

This article is issued from Wikipedia - version of the 10/14/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.